AP5000 more parameter water quality analyzer

The AP5000 parameter water quality analyzer products provided by Aquaread can be used for portable water quality monitoring. The system can configure according to the actual needs include dissolved oxygen, pH, ORP, conductivity (EC), water temperature, turbidity, blue green algae, chlorophyll, water medium oil, cDOM, ammonia nitrogen, chloride, fluoride, nitrogen ions, calcium ions, etc. parameter. The product is very stable in the field of field measurement. It is an ideal on -site water quality monitoring equipment. It has been widely used in the field of water environmental monitoring, hydrology, water conservancy, water, and marine monitoring.

Standard configuration parameters: including solubility, pH, orp, conductivity (EC), water temperature;

Other parameters: Four interfaces, can configure the following parameters at will

AP5000多参数水质分析仪

Optical sensor: turbidity, blue and green algae, chlorophyll, water in water, CDOM,

Ion sensor: ammonia nitrogen, chloride, fluoride, nitrate, calcium ions, etc.

technical parameter

1: dissolved oxygen

AP5000多参数水质分析仪

Measurement range: 0 ~ 50.00 mg/L

Resolution: 0.1% / 0.01mg / L

Accuracy: 0 ~ 20 mg/L: ± 1%of the read; 20 ~ 50 mg/L: ± 10%

2: temperature

Measurement range: -5 ~ 50 ℃

Resolution: 0.01 ℃

Accuracy: ± 0.1 ℃

3: conductivity

Measurement range: 0 ~ 200 ms/cm

Resolution: 3 scale: 0 ~ 9999S/cm; 10.00 ~ 99.99 ms/cm; 100.0 ~ 200.0ms/cm;

Accuracy: ± 1%or ± 1us/ cm of the reading

4: ORP

Measurement range: ± 2000mv

Resolution: 0.1mv

Accuracy: ± 5mv

5: pH

Measurement range: 0 ~ 14 pH /± 625mv

Resolution: 0.01 pH / ± 0.1MV

Accuracy: ± 0.1 pH / ± 5mv

6: turbidity

Measurement range: 0 ~ 3000 NTU

Resolution: 2 scale: 0.0 ~ 99.9 ntu; 100 ~ 3000 ntu

Accuracy: ± 5% of the readings

7: chlorophyll

Measurement range: 0 ~ 500范g/L

Resolution: 2 scale: 0.00-99.99 µg/L; 100.0 ~ 500.0 µg/L

8: Algae blue protein (fresh water)

Measurement range: 0 ~ 300,000 cells/ml

Resolution: 1 cell/ml

Accuracy: ± 10% of the readings

9: Algae red protein (seawater)

Measurement range: 0 ~ 200,000 cells/ml

10: Roddam

Measurement range: 0 ~ 500 μg/L

Resolution: 2 scale: 0.00 ~ 99.99 µg/L; 100.0 ~ 500.0 µg/L

11: Refined oil

Measurement range: 0 ~ 10,000 μg/L

Resolution: 0.1 μg/L

12: CDOM

Measurement range: 0 ~ 20,000 μg/L (quinine)

Resolution: 2 scale: 0.0 ~ 9,999.9 μg/L; 10,000 ~ 20,000 μg/L

MLD: 10 μg/L (quinine)

13: ammonia nitrogen

Measurement range: 0 ~ 9,000 mg/L

Resolution: 2 scale: 0.00 ~ 99.99 mg/L, 100.0 ~ 8999.9 mg/l

Accuracy: ± 10%or 2PPM of the reading, take the big one

14: nitrate nitrate

Measurement range: 0 ~ 30,000 mg/L

Resolution: 2 scale: 0.00 ~ 99.99 mg/L, 100.0-29999.9 mg/l

15: depth

Measurement range: 0-60m

Resolution: 1cm

Accuracy: ± 0.2%

For more products in the same series, please click:

AS-2000

AS-5000

AS-7000

AP2000

AP7000

Accuracy: ± 5% of the readings

Accuracy: ± 5% of the readings

Resolution: 1 cell/ml

Accuracy: ± 10% of the readings

Accuracy: ± 10% of the readings

Accuracy: ± 10% of the readings

Accuracy: ± 10%or 2PPM of the reading, take the big one